ResultsSimulation ResultsThe stream conditions for the separators are shown in Figure 6.
Figure 6: Stream results AnswerThe flow rate of the outlet liquid stream is approximately 210 lb/hr. The flow rate of the outlet vapor stream is approximately 140 lb/hr. DiscussionBy using 1 stage the outlet phase flow rate are the same as those obtained in the separator tutorial. However, if the number of stages are increased, the flow rates would differ. |
|
|